Display Type |
TFT Color LCD
|
---|---|
Display Size |
12.1"
|
Resolution |
800 x 600 pixels (SVGA)
|
Dot pitch |
W0.3075 X H0.3075mm [W0.01 X H0.01in.]
|
Effective Display Area |
W248 X H186.5mm [W9.76 X H7.34in.]
|
Display Colors |
65,536 Colors (No blink)/16,384 Colors (Blink)
|
Backlight |
When GP Revision 5 and later:
LED (When replacement is required,contact your local GP distributor) When GP Revision 5 and earlier: CCFL (Replaceable)*1 |
Brightness Control |
8 Levels (Adjusted with the touch panel)
|
Contrast Control |
Not applicable
|
Backlight Service Life |
50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50% or backlight starts to blink)
|
Language Fonts |
Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.
|
Character Sizes |
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
|
Font Sizes |
Standard font: Width can be expanded up to 8 times., Height can be expanded up to 8 times.
|
8 x 16 dots |
100 char. X 37 rows
|
16 x 16 dots |
50 char. X 37 rows
|
32 x 32 dots |
25 char. X 18 rows
|
8 x 8 dots |
100 char. X 75 rows
|
Program Area |
FLASH EPROM 132 KB
|
Number of Step |
Equivalent to 15,000 steps*2
|
Variable Area |
SRAM 64 KB (uses lithium battery)*3
|
Application Memory |
FLASH EPROM 16 MB*4
|
Data Backup |
SRAM 320KB (uses lithium battery)*5
|
Clock Accuracy |
±65 sec./month (deviation at room temperature and power is OFF)*6
|
Touch Panel Type |
Resistive Film (analog)
|
Touch Panel Resolution |
1,024 X 1,024
|
Touch Panel Service Life |
1,000,000 times or more
|
Serial (COM1) |
RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
|
Serial (COM2) |
RS-422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, 187.5kbps (MPI), Connector: D-Sub9 (socket)
|
Ethernet (LAN) |
IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45)×1
|
Expansion Unit 1 | |
Expansion Unit 2 | |
USB (TYPE-A) |
Conforms to USB1.1.(TYPE-A conn.) X 2, Power Supply Voltage: DC5V±5%, Output Current: 500mA (max.), Communication Distance: 5m (max.)
|
Expansion Memory | |
CF Card |
Compact Flash CF Card Slot (TYPE-II) X 1
|
Sound Output |
Speaker Output, 70mW (Rated Load: 8Ω, Frequency: 1kHz), Connector: 2-piece terminal block (AUX) X 1
|
AUX Input/Output |
Alarm Output, RUN Output, Buzzer Output, Rated Voltage: DC24V, Rated Current: 50mA, Remote Reset Input, Input Voltage: DC24V, Connector: 2-piece terminal block (AUX) X 1
|
DIO (Sink Type) |
6-Point Input Sink Source, , 2-Point Output Sink, Connector: 12pin
|
2Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity (for screen data) by 1 MB.
3A Lithium battery's lifetime is:
10 years when the battery's ambient temperature is 40 oC or less.
4.1 years when the battery's ambient temperature is 50 oC or less.
1.5 years when the battery's ambient temperature is 60 oC or less.
When used for back up: Approximately 100 days, with a fully charged battery.
Approximately 6 days, with a half-charged battery.
4Capacity available for user application. 8 MB available if the revision of the unit is earlier than Rev. 4, or GP-Pro EX Ver. 2.5 or earlier is used.
5A Lithium battery's lifetime is:
10 years when the battery's ambient temperature is 40 oC or less.
4.1 years when the battery's ambient temperature is 50 oC or less.
1.5 years when the battery's ambient temperature is 60 oC or less.
When used for back up: Approximately 100 days, with a fully charged battery.
Approximately 6 days, with a half-charged battery.
6Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
General Specifications
International Safety Standards |
|
---|---|
Rated Input Voltage |
AC 100 to 240V
|
Input Voltage Limits |
AC 85 to 264V
|
Rated Frequency |
50/60 Hz
|
Rated Frequency Range |
40 to 72 Hz
|
Allowable Voltage Drop |
Shorter than 1cycle (Voltage drop interval must be 1 second or more.)
|
Power Consumption |
AC 100 V: 90 VA or less, AC 240 V: 108 VA or less
|
In-Rush Current |
60 A (max.)
|
Voltage Endurance |
AC1,500V 20mA for 1 minute, (between charging and FG terminals)
|
Insulation Resistance |
DC500V 10MΩ (min.), (between charging and FG terminals)
|
Surrounding Air Temperature |
0 to 50 °C (32 to 122 °F)
|
Storage Temperature |
-20 to 60 °C (-4 to 140 °F)
|
Ambient Humidity |
10 to 90% RH (Wet bulb temperature: 39℃ max. - no condensation.)
|
Storage Humidity |
10 to 90% RH (Wet bulb temperature: 39℃ max. - no condensation.)
|
Dust |
0.1mg/m³ and below (non-conductive levels)
|
Pollution Degree |
For use in Pollution Degree 2 environment
|
Atmosphere |
Free of corrosive gases
|
Air Pressure (altitude range) |
800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
|
Vibration Resistance |
IEC/EN61131-2 compliant, 5 to 9Hz Single amplitude 3.5mm [0.14in.], 9 to 150Hz Fixed acceleration: 9.8m/s², X,Y,Z directions for 10 cycles (100 minutes)
|
Concussion Resistance |
IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times
|
Noise Immunity |
Noise Voltage: 1,500Vp-p, Pulse Duration: 1µs, Rise Time: 1ns, (via noise simulator)
|
Electrostatic Discharge Immunity |
Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3)
|
Grounding |
Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
|
Structure |
Equivalent to IP65f NEMA #250 TYPE 4X/13 (Front surface of embedded panel)*7
|
Installation Configuration |
Embedded panel
|
Cooling Method |
Natural air circulation
|
Weight Approx. |
3.2 kg [7 lb] or less (display unit only)
|
External Dimensions |
W313 X H239 X D56mm, [W12.32 X H9.41 X D2.20in.]
|
Panel Cut Dimensions |
W301.5 x H227.5 mm [W11.87 x H8.96 in.], Panel thickness area: 1.6 to 10 mm [0.06 to 0.39 in.]*8
|
7The front face of the GP unit, installed in a solid panel, has been tested using, conditions equivalent to the standards shown in the specification. Even though the, GP unit's level of resistance is equivalent to these standards, oils that should have, no effect on the GP can possibly harm the unit. This can occur in areas where either, vaporized oils are present, or where low viscosity cutting oils are allowed to adhere, to the unit for long periods of time. If the GP's front face protection sheet becomes, peeled off, these conditions can lead to the ingress of oil into the GP and separate, protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the, front panel’s plastic cover. Therefore, prior to installing the GP be sure to confirm the, type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket, are removed from the panel, the original level of the protection cannot be guaranteed., To maintain the original protection level, be sure to replace the installation gasket, regularly.
8Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].